A radial insertion machine placing an electrolytic capacitor in reverse does not automatically mean the insertion head rotated the part incorrectly. The leaded component may have arrived in a differently oriented tape, been loaded into the feeder from the wrong direction, been assigned an incorrect orientation in the program, or been matched to an outdated PCB drawing. All four paths can produce the same visible result. Quarantine suspect boards before electrical testing: polarized aluminum electrolytic capacitors are not intended to receive reverse voltage.
Keep one affected board at the machine exit, a length of the unused component tape, the reel identification and the active program revision. Mark the affected reference designator and compare the capacitor's negative stripe with the approved assembly drawing and the electrical polarity of the two pads. Do not treat a printed plus sign on an unverified PCB revision as the only source of truth.
The distribution tells you where to look next. If every board has the same reference designator reversed, review its program assignment and the current PCB revision. If several reference designators share one feeder and all show the same problem, inspect the tape and station configuration. A few reversed pieces appearing around a tape splice point deserve a different investigation from a whole reel that is consistently oriented the other way.
Stop the affected operation and trace the potentially affected board range. Boards that have already been powered need an engineering disposition; simply pulling out and reinserting the capacitor does not establish that the component is sound. Follow the site's isolation and discharge procedure before handling assemblies.
Compare the negative stripe and both leads on the current reel against the approved physical sample. Check whether orientation changes at the splice, after a reel change, or between approved suppliers. A familiar value and case size do not guarantee identical tape orientation, lead geometry or feeder compatibility. If individual parts are reversed within one reel, retain the segment for incoming-quality review. If the whole reel is consistent but differs from the accepted sample, confirm the part number, packing specification and loading instruction.
Next trace how the tape enters the feeder. Confirm that the feeder ID matches the work order, that the intended end of the tape enters the feed path and that the pick position presents the same physical polarity as the qualified first article. Test with verified material under an approved low-speed setup. If the fault follows the reel, investigate material and splicing; if it stays with the station, inspect the feeder installation, presentation and station mapping on the vertical inserter; feeder and gripper parts are listed by model in our spare parts section. Never defeat guarding to observe moving mechanisms.

Review reference designator, feeder assignment, insertion direction, any head rotation and the loaded program revision together. A displayed angle of zero degrees has no independent meaning unless the board coordinate system, panel direction and tape presentation are all defined. Mirrored panels, a changed board entry direction or a copied recipe can reverse the physical result without changing what the operator sees on one program screen.
Draw the full chain for one sample: negative stripe on tape → negative stripe at pickup → orientation after handling/forming → actual pad on the PCB. A board-positioning camera may correct placement coordinates but does not, by itself, verify the polarity marking on the capacitor. Confirm whether this machine and this part have a validated polarity-recognition function before relying on it. Change one controlled setting, insert a first article, and check both the upper-side polarity and underside lead condition before resuming the lot.
Record board and panel orientation, reference designator, reel lot, feeder station, program revision, actual negative-stripe direction and sign-off. Repeat polarity confirmation after changing reels, station assignments or PCB revision; document special instructions for alternate approved tape orientations. For assemblies that have already passed through the soldering stage, evaluate the part, plated-through holes and pads as part of the rework disposition rather than assuming that a visually corrected orientation restores reliability.
Q1: Does a capacitor's negative stripe facing the PCB plus mark always prove a reverse insertion?
It is a serious warning, but first verify that the silkscreen matches the approved drawing and the actual pad polarity. Do not power the board until the discrepancy is resolved.
Q2: Only a few capacitors in one reel are reversed. Should we change the program?
No global program change should be made on that evidence alone. Quarantine the affected tape segment and check component orientation and splice history. A program change would affect all parts at that reference designator.
Q3: Does a vision camera remove the need for a polarity first-article check?
Only if the camera is specifically configured and validated to inspect this capacitor's polarity mark. PCB fiducial recognition is not equivalent to component polarity recognition.
For electrolytic capacitor polarity errors on a radial inserter, close the investigation with a documented orientation chain and before-and-after physical samples, not merely a note saying that the program angle was changed.